work1000
Efficiency
Item
SUN2000-75KTL-C1SUN2000-70KTL-C1

Maximum efficiency
99.00%

Chinese efficiency
98.50%

Input
Item
SUN2000-75KTL-C1SUN2000-70KTL-C1

Maximum input power
84,200 W78,600 W

Maximum input voltagea
1100 V

Operating voltage rangeb
200–1000 V

Maximum input current (per MPPT)
25 A22 A

Maximum input current (per string)
18 A

Maximum short-circuit current (per MPPT)
39 A30 A

Maximum SUN2000 backfeed current to the PV array
0 A

Full power MPPT voltage range
625–850 V

Rated input voltage
750 V

Number of inputs
12

Number of MPP trackers
6

Note a: The maximum input voltage is the upper threshold of the DC voltage. If the input voltage exceeds the threshold, the solar inverter may be damaged.


Note b: If the input voltage is beyond the operating voltage range, the solar inverter cannot work properly.


Output
Item
SUN2000-75KTL-C1SUN2000-70KTL-C1

Rated active power
75 kW70 kW

Rated active power
82.5 kVA77 kVA

Maximum active power (cosφ = 1)
82.5 kW77 kW

Rated output voltage
288 V/500 V, 3W+PE

Rated output current
86.7 A80.9 A

Adapted grid frequency
50 Hz

Maximum output current
95.3 A89 A

Power factor
0.8 leading… 0.8 lagging

Maximum total harmonic distortion (rated power)
< 3%

Protection
Item
SUN2000-75KTL-C1SUN2000-70KTL-C1

Input DC switch
Supported

Anti-islanding protection
Supported

Output overcurrent protection
Supported

Input reverse polarity protection
Supported

PV string fault detection
Supported

DC surge protection
Type II

AC surge protection
Type II

Insulation resistance detection
Supported

RCMU
Supported

Overvoltage category
PV II/AC III

Built-in PID repaira
Not supportedOptional

Note a: When the SUN2000 is disconnected from the grid and stops working, the built-in PID can achieve the PV– positive offset of the PV module. (PV– positive offset refers to raising the voltage between PV– and the ground to above 0 V through voltage compensation.) When designing a power plant, confirm with the PV module manufacturer that the anti-PID voltage compensation direction of the PV module is the same as the direction of the PV– positive offset. Otherwise, PV modules may be damaged.


Display and Communication
Item
SUN2000-75KTL-C1SUN2000-70KTL-C1

Display
LED indicator, Bluetooth module+app, USB data cable+app, and WLAN module+app

RS485
Optional

MBUS
Supported

Common Parameters
Item
SUN2000-75KTL-C1SUN2000-70KTL-C1

Dimensions (W x H x D)
1075 mm x 555 mm x 300 mm

Net weight
73 kg±1 kg

Operating temperature
–25°C to +60°C

Cooling mode
Natural convection

Maximum operating altitude
4000 m

Humidity
0%–100% RH

Input terminal
Amphenol Helios H4

Output terminal
Cable gland+OT terminal

Ingress Protection Rating
IP65

Topology
Transformerless

What can Vesol do?

  • High Quality Products
  • DDP Service
  • Friendly and Professional Customer Service
  • Solar system solution design
  • Solar inverter, lithium battery storage system also are available.
  • Multiple payment supported(T/T, Paypal, XTransfer, L/C, Western Union, D/P etc. )


GET A PROFESSIONAL QUOTE